AD-3213EX
Ultrasonic Flaw Detector



Range

2.5~10,000mm (resolution: 0.1mm)
0.1~500 inches (resolution: 0.01 inches)

Range Step

2.5/5/10/25/50/125/250/500/1,000/2,500/5,000/10,000mm/Continuous m/s
0.1/0.2/0.5/1/2/5/10/20/50/100/200/500 inches/Continuous

Velocity

100~19,999 (4~800 inches)

Probe Delay

0~200ms

Display Start

-100~9,900mm (DAC Curve Mode fixed at 0mm)

Gain

0~100dB

Gain Step

0.1/6dB

Test Mode

Pulse Echo/Transmit Receive

Pulse Energy

High/Low (Square Pulse -350/-50V)

Pulse Width

50~275ns STEP (automatically related to frequency)

Damping

25/50/100/400½

Pulse Repetition

500Hz maximum (fast)/200Hz maximum (middle)/100Hz maximum (slow)

Band Width

0.1 to 10MHz (-3dB)
0.05 to 15MHz (-6dB)
Broad Band (equivalent sample frequency = 200MHz@BB)
0.5/1/2/5/10MHz 5 narrow Band (equivalent frequency ³ 20 x Band Width)

Rejection

0~80%

Rectification Mode

V±/V+/V-/(RFRange ² VELO x 140/f2/2 = 5920 x 140/5M/2/2 = 41.44mm)

Vertical Linearity

±3% (JIS)

Unit

Metric/Inches

Gate

1 gate/2 gates/DAC Curve (Stop and Start is variable)

Gate Calculation

y, d, W, differential, %, dB (Cross Peak)

DAC Curve

10 points maximum

Setting Memory

20

Data Memory

100 (Data + WAVE + Graph)

Interface

RS-232C

Operating Temperature

0°~40°C


 

Color Liquid Crystal Display

60 Hz Response Time

DAC Curve

  • Meets ASME, AWS & JIS specifications
  • On-screen display of y, d and W data
  • Buzzer warns when data is beyond specifications

Standard Gate Functions

  • Dual gate
  • Single gate
  • DAC Curve
  • Gate calculation using y, d, W, differential, % or dB

 

NiCd Battery with Power Management

  • 4 hours operation on full charge
  • On-screen bar graph & numeric display
  • LSI power management in power pack

 

Data Memory

  • 100 data sets including waveform, graphics & data table
  • 10 character alpha-numeric remarks per data set
  • Stores calibration data for 20 different probes

 

Standard Serial Communications

  • RS-232C interface port to computer or graphic printer
  • Optional serial to parallel adapter

 

Automatic Self Calibration